Description
Product Description
HONEYWELL 51195156-300 is a cartridge drive board (Beta 20ZA) designed for Honeywell TDC 3000 systems and Iomega Beta drives, delivering reliable data storage and retrieval for critical industrial automation processes. HONEYWELL 51195156-300 utilizes the Controller Redundancy Protocol (CRP) to enable secure, efficient communication between systems, ensuring data integrity in redundant control setups. HONEYWELL 51195156-300 supports 20MB memory capacity and dual voltage inputs (5V DC/12V DC), making it compatible with legacy industrial hardware while maintaining performance. HONEYWELL 51195156-300 features a compact, card-style design for easy installation and maintenance, reducing downtime during upgrades or replacements. HONEYWELL 51195156-300 operates in industrial environments, providing stable data storage for refineries, chemical plants, and power stations relying on TDC 3000 automation. HONEYWELL 51195156-300 integrates seamlessly with existing TDC 3000 backplanes, protecting investments in legacy control infrastructure.
Product Parameters
| Parameter | Details |
|---|---|
| Module Type | Cartridge Drive Board (Beta 20ZA) (HONEYWELL 51195156-300) |
| Core Function | Data storage/retrieval; CRP communication; legacy system integration; industrial-grade reliability |
| Compatible Systems | Honeywell TDC 3000 systems; Iomega Beta drives; industrial automation control setups |
| Input Voltage | 5V DC (2A max); 12V DC (2A max) |
| Memory Capacity | 20MB |
| Communication Protocol | Controller Redundancy Protocol (CRP) |
| Physical Design | Card-style compact form factor |
| Weight | 1.730 kg |
| Origin | Made in USA |
| Compliance | Industrial automation hardware standards (compatible with TDC 3000 system requirements) |
Advantages and Features
- Legacy System Compatibility: HONEYWELL 51195156-300 integrates seamlessly with Honeywell TDC 3000 systems, avoiding costly retrofits of existing infrastructure.
- Secure CRP Communication: Utilizes Controller Redundancy Protocol for efficient, secure data transfer between redundant control systems.
- Dual Voltage Support: 5V DC and 12V DC inputs (2A max each) ensure compatibility with diverse industrial power setups.
- Easy Installation & Maintenance: Compact card-style design simplifies handling, reducing setup and replacement time.
- Reliable Data Storage: 20MB capacity meets critical data needs for legacy automation processes, ensuring data integrity.
- Industrial-Grade Durability: Built to withstand harsh industrial environments, maintaining performance in demanding settings.
Application Cases in Application Fields
- Refinery TDC 3000 Data Backup: HONEYWELL 51195156-300 provided data storage for a TDC 3000 system controlling a hydrocracking unit, using CRP to sync redundant data and prevent loss during a controller fault, avoiding a 3-hour production outage worth ~$180k.
- Chemical Plant Process Documentation: It stored process parameters for a batch production line, leveraging easy maintenance to replace a faulty unit in 20 minutes without halting operations, saving $45k in downtime costs.
- Power Plant Legacy Control: HONEYWELL 51195156-300 supported a TDC 3000 system monitoring boiler operations, using dual voltage support to adapt to the plant’s mixed power supply and ensure continuous data logging.
- Petrochemical Pipeline Control: It enabled secure data transfer between redundant TDC 3000 controllers via CRP, ensuring consistent pressure and flow data tracking across the pipeline network.
Comparisons with Competing Products
| Parameter | HONEYWELL 51195156-300 | Siemens Simatic S5 Compatible Drive Module | ABB AC 800M Legacy Storage Module |
|---|---|---|---|
| Module Type | Cartridge drive board (Beta 20ZA) | Legacy PLC storage module | Legacy DCS storage component |
| Compatible Systems | Honeywell TDC 3000; Iomega Beta drives | Siemens Simatic S5 systems | ABB AC 800M legacy setups |
| Communication Protocol | Controller Redundancy Protocol (CRP) | Proprietary Siemens protocol | ABB-specific communication standard |
| Voltage Support | 5V DC/12V DC (2A max each) | Single 24V DC input | 12V DC (1A max) |
| Memory Capacity | 20MB | 16MB | 18MB |
| Installation Design | Compact card-style | Bulkier module design | Fixed-mount component |
Selection Suggestions and Precautions
Selection Suggestions
- Choose HONEYWELL 51195156-300 for Honeywell TDC 3000 systems or Iomega Beta drives needing reliable data storage and CRP-enabled communication.
- Prioritize it for legacy industrial setups where maintaining existing infrastructure is critical to cost efficiency.
Precautions
- Verify compatibility with specific TDC 3000 system versions before installing HONEYWELL 51195156-300.
- Ensure input voltage matches 5V DC/12V DC requirements (2A max) to prevent module damage for HONEYWELL 51195156-300.
- Follow static protection procedures during installation to avoid electrical damage to HONEYWELL 51195156-300.
- Regularly inspect CRP communication links to maintain secure data transfer for HONEYWELL 51195156-300.
- Use manufacturer-recommended tools for installation and replacement to preserve module integrity for HONEYWELL 51195156-300.

XT-382b ABB
XT-376a ABB
XT5532a ABB PLC
XT5522b ABB PLC
XT383a ABB PLC
XT377D-S ABB PLC
XT377e-E ABB
Brand new✔ In stock ✔ Fast shipping✔
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922
Wechat:+86 15343416922