Description
Product Description
Product Parameters
- Brand/Model: FOXBORO FCM2F2
- Core Communication Parameters
- Supported Protocol: Foundation Fieldbus H1 (IEC 61158-2)
- Number of Ports: 2× redundant Foundation Fieldbus H1 ports
- Communication Speed: 31.25 kbps (Foundation Fieldbus H1 standard)
- Maximum Nodes per Port: 32 Fieldbus devices (per H1 segment)
- Cable Compatibility: Twisted-pair shielded cable (AWG 18-24), conforming to Foundation Fieldbus H1 specifications
- System & Diagnostic Parameters
- Compatible Systems: Foxboro I/A Series DCS (FCP270, FCP280, FCP400 controllers)
- Diagnostic Functions: Segment fault detection, device health monitoring, communication error logging, LED status indicators (per port)
- Redundancy: Hot standby redundancy (automatic failover between H1 ports)
- Configuration: Foxboro I/A Series Workbench, Fieldbus Configuration Tool (FCT)
- Environmental & Physical Parameters
- Operating Temperature: 0°C ~ +60°C
- Storage Temperature: -40°C ~ +85°C
- Vibration Resistance: 5g (10-2000Hz, IEC 60068-2-6)
- Shock Resistance: 30g (11ms half-sine wave)
- Power Supply: 5V DC (from I/A Series chassis), power consumption ≤ 8W
- Protection Grade: IP20 (rack-mount installation)
- Dimensions: 100mm (W) × 200mm (H) × 150mm (D) (I/A Series chassis-compatible)
- Installation: Hot-swappable (Foxboro certified chassis)
Advantages & Features
- Dual Redundant H1 Ports: FOXBORO FCM2F2 offers hot standby redundancy for Foundation Fieldbus H1 communication, ensuring automatic failover to the secondary port if the primary port or segment fails—critical for uninterrupted process control in refineries and chemical plants.
- Advanced Fieldbus Diagnostics: Real-time monitoring of segment health, device status, and communication errors enables proactive troubleshooting, reducing mean time to repair (MTTR) and minimizing unplanned downtime.
- Native I/A Series Integration: Fully compatible with Foxboro I/A Series controllers and engineering tools, the module requires no third-party software for configuration, streamlining system deployment and maintenance.
- Compliance with Industry Standards: Adheres to Foundation Fieldbus H1 (IEC 61158-2) specifications, ensuring interoperability with all certified Fieldbus devices (e.g., Rosemount transmitters, Fisher valves) and future-proofing system upgrades.
Application Fields & Cases
- Oil Refinery Process Control: A major oil refinery deployed FOXBORO FCM2F2 modules in its Foxboro I/A Series DCS to connect 64 Foundation Fieldbus H1 devices (pressure/temperature transmitters, flow meters) across two redundant segments in a crude distillation unit. The dual redundant ports prevented communication loss during a primary segment cable failure, ensuring continuous process monitoring and control.
- Chemical Plant Batch Processing: A petrochemical facility used FOXBORO FCM2F2 to integrate Foundation Fieldbus-enabled reactor temperature controllers and level transmitters into its I/A Series DCS. Advanced diagnostics identified a faulty transmitter early, allowing maintenance before a batch quality issue occurred, and reducing waste by 15%.
- Power Generation Emissions Monitoring: A combined-cycle power plant integrated FOXBORO FCM2F2 with Fieldbus-based gas analyzers (NOx, CO2) to monitor emissions in real time. The module’s redundant communication ensured compliance with environmental regulations by preventing data gaps during network outages, avoiding costly fines.
Competitor Comparison
| Comparison Dimension | FOXBORO FCM2F2 | Competitor 1 (Emerson DeltaV FCM) | Competitor 2 (Siemens PCS 7 Fieldbus Module) |
|---|---|---|---|
| Redundancy | Dual H1 ports (hot standby) | Single H1 port (optional redundancy) | Single H1 port (redundancy via separate module) |
| Diagnostic Capabilities | Segment/device health monitoring | Basic error logging | Limited device status tracking |
| System Compatibility | Foxboro I/A Series DCS | Emerson DeltaV DCS | Siemens PCS 7 DCS |
| Max Nodes per Segment | 32 | 32 | 32 |
| Core Advantages | Native redundancy, advanced diagnostics | DeltaV ecosystem integration | Siemens PLC/DCS compatibility |
Selection Suggestions & Precautions
- Selection Suggestions: FOXBORO FCM2F2 is the ideal choice for Foxboro I/A Series DCS users needing redundant Foundation Fieldbus H1 connectivity with advanced diagnostics (e.g., oil & gas, chemical processing). For Emerson DeltaV DCS, choose Emerson DeltaV FCM; for Siemens PCS 7 systems, select Siemens PCS 7 Fieldbus modules.
- Precautions:
- Use only Foundation Fieldbus H1-certified twisted-pair shielded cable (AWG 18-24) to ensure reliable communication and compliance with standards.
- Limit the number of devices per segment to 32 (per Foundation Fieldbus specifications) to avoid communication bottlenecks or signal degradation.
- Configure redundant H1 ports via Foxboro I/A Series Workbench to enable automatic failover—verify failover functionality after installation to ensure redundancy works as expected.
- Follow Foxboro hot-swappable procedures when replacing the module to avoid disrupting the DCS chassis or other modules.
- Regularly check LED status indicators and diagnostic logs to identify segment faults or device issues before they impact process control.


DF9200722-C1 PLC
JANCD-CU06 PLC
JANCD-I004B
JANCD-CPOIB PLC
JANCD-1003C PLC
JANCD-XIO01 PLC
JANCD-FC224 PLC
JANCD-SR02
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922
Wechat:+86 15343416922