ABB B3EA HENF315147R1 is an industrial-grade AC contactor designed for remote switching and basic overload protection of three-phase power circuits, specifically tailored for high-power loads such as electric motors, heating elements, and industrial pumps. As a key model in ABB’s B3EA contactor series, it stands out for its robust arc-suppression capability, long-lasting contact design, and seamless compatibility with ABB’s automation ecosystem—making it indispensable in water treatment plants, manufacturing assembly lines, and small-scale power distribution systems. Its reliable performance directly ensures the continuous operation of critical industrial equipment, as any failure in power circuit switching could lead to costly production downtime.
At its core, ABB B3EA HENF315147R1 uses an electromagnetic coil to control the opening and closing of its main contacts, enabling remote operation via signals from PLCs (e.g., ABB AC500/AC800M) or manual control panels. It features 3 normally open (NO) main contacts for carrying the primary load current and 1 NO + 1 normally closed (NC) auxiliary contact for status feedback—this allows integration with SCADA or HMI systems to monitor whether the contactor is energized. The contactor’s silver-tin alloy contacts are engineered to withstand short-term inrush currents up to 80A, making it ideal for inductive loads like motor startups, where current spikes are common. Additionally, ABB B3EA HENF315147R1 supports a wide coil voltage range (85–110% of rated voltage), ensuring stable operation even in unstable industrial power grids. For detailed technical specifications and documentation, visit the official resource: [Link to ABB B3EA HENF315147R1](Insert actual product link here).
Key Technical Specifications
Specification Category | Details |
---|---|
Main Circuit Parameters | Rated current: 16A (400V AC, cosφ=0.8); Rated voltage: 690V AC; Short-time withstand current: 80A (≤1s) |
Contact Configuration | Main contacts: 3x NO; Auxiliary contacts: 1x NO + 1x NC |
Coil Parameters | Rated voltage: 230V AC; Power consumption: 18VA; Operate time: ≤60ms; Release time: ≤40ms |
Environmental Resistance | Operating temperature: -25°C to +60°C; Relative humidity: ≤95% (non-condensing); Protection class: IP20 (for enclosure mounting) |
Mechanical & Installation | DIN rail mounting (45mm width); Dimensions: 45mm × 100mm × 80mm (W×H×D); Weight: ~0.5kg |
Certifications & Standards | Complies with IEC 60947-4-1 (Industrial contactors) and EN 61000-6-2 (EMC for industrial environments) |
Core Advantages & Features
- Durable Contact Design: The silver-tin alloy contacts of ABB B3EA HENF315147R1 offer a mechanical lifespan of up to 1 million switching cycles—twice that of standard copper contacts. This reduces maintenance frequency, especially in 24/7 applications like municipal water pump stations, where the contactor may switch multiple times per hour.
- Wide Voltage Tolerance & Anti-Interference: The coil operates reliably within 85–110% of its rated voltage, preventing frequent on/off cycling in unstable power grids (e.g., peak industrial hours with voltage dips). Internal magnetic shielding also protects against electromagnetic interference (EMI) from nearby inverters or motors, eliminating false triggers.
- Seamless ABB Ecosystem Compatibility: ABB B3EA HENF315147R1 integrates directly with ABB PLCs and TNR series thermal overload relays without additional adapters. For example, if a TNR relay detects motor overcurrent, it immediately cuts power to the contactor coil, triggering a “overload-protection-shutdown” loop with a response time ≤100ms.
- Compact Size & Easy Maintenance: Its 45mm narrow profile saves space in electrical enclosures, allowing multiple contactors to be mounted on a single DIN rail. A top-mounted LED indicator lets technicians check coil energization status without opening the enclosure, simplifying troubleshooting.
Typical Application Scenarios
- Municipal Water Pump Motor Control: In residential secondary water supply systems, ABB B3EA HENF315147R1 controls a 7.5kW water pump (rated current ~14A). A PLC sends “energize/de-energize” signals to the contactor coil based on tank level sensor data: when the water level drops below the threshold, the main contacts close to start the pump; when full, the coil de-energizes to stop it. Auxiliary contacts feed pump status to an HMI for remote monitoring.
- Heating Module Switching in Automotive Production: In automotive paint-drying processes, multiple heating tubes (total power 5kW, rated current ~12A) need to alternate operation per process timing. ABB B3EA HENF315147R1 acts as a switch for the heating circuit, receiving timed signals from a PLC to switch modules. Its ≤40ms release time prevents current overlap between modules, avoiding circuit overload.
- Small Generator Power Distribution: In a 10kW diesel generator system, ABB B3EA HENF315147R1 works with an ATS (Automatic Transfer Switch) to switch power sources. When grid power fails, the contactor closes quickly to feed generator power to loads; when the grid recovers, it releases instantly to prevent “grid-generator parallel short circuits.” Its 80A short-time withstand current handles generator startup inrush.
Competitor Comparison (vs. Same-Spec Contactors)
Comparison Dimension | ABB B3EA HENF315147R1 | Siemens 3RT2026-1KB0 | Rockwell 100-C16*10D |
---|---|---|---|
Auxiliary Contact Configuration | 1NO + 1NC (flexible status feedback) | 1NO only (requires expansion module) | 1NO + 1NC |
Coil Voltage Tolerance | 85–110% rated (strong voltage dip resistance) | 90–110% rated (limited dip tolerance) | 85–110% rated |
Release Time | ≤40ms (fast circuit cutoff) | ≤50ms (slower for inductive loads) | ≤45ms |
PLC Compatibility | Directly compatible with ABB AC500/800M (no adapters) | Requires PROFINET module | Requires Rockwell 1756 I/O module |
Mechanical Lifespan | 10 million cycles (per DIN EN 60947-4-1) | 8 million cycles | 8 million cycles |
Selection Recommendations & Usage Precautions
1. Selection Recommendations
- Load Matching: ABB B3EA HENF315147R1 (16A rated) is suitable for 3-phase motors ≤7.5kW (400V) or resistive loads ≤10kW (e.g., heaters). For frequently starting motors (e.g., compressors), reserve 20% current headroom to avoid contact overheating.
- Ecosystem Alignment: Prioritize ABB B3EA HENF315147R1 if ABB PLCs (e.g., AC500) or TNR thermal relays are already in use—this eliminates compatibility issues and simplifies “overload protection” wiring.
- Environmental Fit: For dusty or humid environments (e.g., food processing plants), mount the contactor in an IP54+ enclosure to protect contacts from moisture and debris.
2. Usage Precautions
- Wiring Standards: Use copper wires ≥2.5mm² for main circuits, and torque terminals to 2.5N·m to prevent loose connections (which cause overheating). Install a 10A fuse in the coil circuit to protect against short circuits.
- Regular Maintenance: Inspect contacts every 6 months—replace the contactor if contacts are blackened or pitted. Clean dust from terminals with a dry brush (power off first).
- Avoid Overloading: Do not use ABB B3EA HENF315147R1 for loads exceeding 16A (e.g., 11kW motors). For higher-power applications, select larger B3EA models (e.g., 25A rated).
B3EA
Brand new✔ In stock ✔ Fast shipping✔
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours